Knowledge check
PINK Device & Kiosk (Wizard) Mode
12 questions in pool · live exam draws 5
SPMED01
Q1 multiple-choice · device-identity PINK is best described as:
Source: SPMED01 §1 — What PINK is.
Explanation: PINK is single-purpose: clinical mastectomy session photography on a low-platform turntable. Not a general product machine, not a 3D scanner.
Q2 multiple-choice · components Which of the following is NOT part of the PINK device that the operator interacts with?
Source: SPMED01 §1 + §2 — Components vs scope boundary.
Explanation: PINK’s session record is sent to the clinic’s records system per the configured integration, but the operator does not directly interact with that EMR system. Operator’s scope ends at the kiosk-confirmed save.
Q3 multiple-choice · kiosk-wizard Why does PINK use a kiosk (wizard) mode instead of a free-form software interface?
Source: SPMED01 §3 — Kiosk (wizard) mode.
Explanation: The wizard exists so every session looks the same, the operator can’t accidentally skip a step, and a new operator can run a session without prior software experience.
Q4 multiple-choice · wizard-sequence In the typical PINK wizard sequence, what comes immediately AFTER the capture rotation completes?
Source: SPMED01 §3 — Typical 8-step sequence.
Explanation: The optional videocall step (if enabled by clinic config) sits between capture and session-complete. The save + return-to-idle happens at the end.
Q5 true-false · configuration-vs-preference The operator can adjust whether at-source anonymization is applied during a session.
Source: SPMED01 §4 — Configuration per clinic policy.
Explanation: Anonymization rules are clinic configuration, not operator preference. Operator does not toggle anonymization on or off.
Q6 multiple-choice · device-states During a session, the operator notices the camera indicator light remains on AFTER the videocall ended. Best classification:
Source: SPMED01 §5 + §7 — Device states + escalation.
Explanation: A camera indicator outside an active videocall is a hard escalate. Privacy boundary depends on hardware behaving as expected.
Q7 multiple-select · daily-rhythm Which of the following belong to the operator’s START-of-day routine on PINK? (Select all that apply.)
Source: SPMED01 §6 — Daily operating discipline.
Explanation: Operator never routinely accesses prior session records — out of scope. All four other items are part of the start-of-day prep.
Q8 multiple-choice · escalation The emergency stop button feels less responsive than yesterday but still triggers. Operator should:
Source: SPMED01 §7 — When to escalate.
Explanation: Safety-critical controls degrade before they fail. A change in feel is a leading indicator. Suspend + escalate; don’t run patients past warning signs.
Q9 multiple-choice · operator-scope A clinical staff member asks the operator to “save the unanonymized version” of a session for the surgeon’s notes. Correct response:
Source: SPMED01 §4 + §7 + SPMED02 cross-ref.
Explanation: Operator does not override clinic config at the request of clinical staff. If unanonymized data is genuinely needed, that’s a clinic-level + PhotoRobot policy conversation, not a session-floor decision.
Q10 true-false · privacy-boundary The PINK videocall camera + microphone are active any time the device is powered on.
Source: SPMED01 §2 + SPMED04 §2.2 — Privacy boundary.
Explanation: Videocall hardware operates only during an active, explicitly initiated videocall step. Hardware-level off outside that step, by design.
Q11 multiple-choice · fault-recovery The kiosk shows a “fault — capture frame missed, please re-run” message mid-session. Patient is still on the platform. Best operator response:
Source: SPMED01 §3 + §5 — Wizard recovery + state handling.
Explanation: Wizard has a defined recovery path for missed frames. Use it. Keep the patient informed during recovery.
Q12 multiple-choice · scope-boundary What is the operator’s authority during a session if the patient asks a clinical question (e.g., “is this swelling normal?”)?
Source: SPMED01 §1 + §7 + SPMED02 cross-ref.
Explanation: Operator handles the device; clinical staff handle clinical content. Acknowledge the patient’s question respectfully + redirect to the appropriate channel.
Ready to commit? You can review and change your answers before submitting. Once submitted, this attempt is final and we'll show you your score, correct answers, and explanations.
Submit final answers